Rail Glazing Compliance: A Practical Guide to FRA 49 CFR Part 223
Part 223 is performance-based. It defines the impact tests, the certification, and the marking, and it does not name a material, so compliance comes down to test data that matches the glazing being installed.
In This Article
FRA 49 CFR Part 223 sets minimum glazing requirements for locomotives, passenger cars, and cabooses, with the stated purpose of protecting railroad employees and passengers from injury when objects strike the windows.[1] The regulation is performance-based. It defines the impact tests a glazing material must pass, how the manufacturer certifies the result, and how installed glazing must be marked. It does not name a required material.
For a rail OEM, compliance means matching each window position to the right certification type, having access to test verification data that covers the glazing construction actually being installed, and meeting the related window requirements in Part 238 for passenger equipment. This post walks through each of those.
Where Part 223 Applies
Part 223 applies to railroads operating rolling equipment on standard gauge track that is part of the general railroad system of transportation. It excludes rapid transit operations in an urban area that are not connected to the general railroad system, along with equipment that operates only on track inside an installation outside that system.[1]
Commuter rail and intercity passenger service fall inside the rule. Standalone light rail and subway systems that are not connected to the general railroad system are generally outside Part 223, while shared-use operations on general system track can fall under FRA jurisdiction. The connection question is answered for the specific operation, not by vehicle type.
For equipment built or rebuilt after June 30, 1980, Part 223 requires certified glazing in all locomotive cab windows, all caboose windows, and all passenger car windows, with at least four emergency windows in each passenger car.[1]
Type I and Type II Glazing Locations
The certification type follows the window's orientation. Any panel that could meet either definition because of its curvature is treated as end-facing.[1]
Required where a line perpendicular to the glazing makes a horizontal angle of 50 degrees or less with the centerline of the vehicle. Large object impact: a cinder block of at least 24 lbs striking corner-first at a minimum of 44 ft/s, or a steel ball of at least 12 lbs at a minimum of 62.5 ft/s.
For glazing used only where that angle is more than 50 degrees. The coupled ends of multiple-unit locomotives and other semi-permanently connected equipment count as side-facing, as do end doors other than those at the cab end of a cab car or MU locomotive. Large object impact: the same cinder block at a minimum of 12 ft/s, or the steel ball at a minimum of 17 ft/s.
Both regimens include the same ballistic test: a standard 22 caliber long rifle lead bullet weighing 40 grains, at a minimum of 960 ft/s.[1]
A test passes when the projectile does not penetrate the back surface of the glazing and no particles from the back side pass through an aluminum witness plate mounted six inches behind it. Partial penetration of the impact surface does not count as a failure.[1]
How Part 223 Certification Works
The glazing manufacturer certifies that each type of glazing material it supplies for compliance has passed the Appendix A tests, and makes the test verification data available to a railroad or to FRA on request. Appendix A does not describe a separate FRA approval step. The data must include the original data logs and documentation showing that specimen selection, test setups, measuring devices, and procedures were handled by qualified personnel using recognized and acceptable practices.[1]
Test Specimens
Each test specimen must be a full-scale sample of the largest dimension the manufacturer intends to produce and install, representative of production material, and selected on a documented random basis. Three specimens go through the ballistic test and two through the cinder block test. When the steel ball is used, four specimens are tested and three of the four must pass. Under the standard procedure, specimens must pass the required tests consecutively, and a failure below the minimum velocity ends the test and fails the material.[1]
Certification attaches to a glazing material type tested at its largest production size. A larger window or a different laminate build falls outside what the test data shows.
A rail program should confirm that the supplier's test data covers the construction, thickness, and maximum panel size being ordered.
Marking and Installation
Each unit of certified glazing must be permanently marked before installation, in a way that stays visible after installation, with “FRA Type I” or “FRA Type II,” the manufacturer, and the type or brand identification of the material. Part 223 also defines certified glazing as material that is installed so that it will perform its intended function,[1] which brings the frame and mounting into the compliance picture.
Part 238 Window Requirements for Passenger Equipment
Part 223 directs passenger equipment to Part 238 for additional emergency window and safety glazing requirements.[1]
Tier I and Tier II Glazing
For Tier I passenger equipment, Section 238.221 requires each exterior window on a locomotive cab and passenger car to remain in place under the forces described in Part 223, and under the air pressure differences created when two trains pass at the minimum separation for adjacent tracks, traveling in opposite directions at maximum authorized speed.[2]
For Tier II passenger equipment, Section 238.421 applies Part 223 to exterior windows, with stated exceptions, and adds an end-facing requirement. Each end-facing exterior window on a passenger car and power car cab must also resist the impact of a 12-pound solid steel sphere traveling at the maximum speed at which the car will operate, with no penetration or spall, demonstrated with a 0.001-inch aluminum witness plate placed 12 inches from the window. The glazing must be marked "FRA TYPE IHP."[3]
Emergency and Rescue Access Windows
Section 238.113 requires at least four emergency window exits in each single-level passenger car, designed for rapid and easy removal from inside the car without a tool. Cars ordered on or after September 8, 2000, or placed in service for the first time on or after September 9, 2002, need an unobstructed opening of at least 26 inches horizontally by 24 inches vertically at each emergency window exit, with limited exceptions.[4]
Section 238.114 adds rescue access windows, a minimum of two in each single-level car, which an emergency responder must be able to remove without unreasonable delay. The same 26 by 24 inch minimum opening applies to rescue access windows in cars ordered on or after April 1, 2009, or placed in service for the first time on or after April 1, 2011.[5] Glazing built to pass Type I or Type II impact tests is hard to break by design, so emergency and rescue windows depend on a removal method engineered into the window, gasket, and frame.
Flammability and Smoke
Appendix B to Part 238 sets flammability and smoke emission test methods and performance criteria for materials used in passenger cars and locomotive cabs, including ASTM E 162 for surface flammability and ASTM E 662 for smoke optical density. For double window glazing, only the interior glazing is required to meet those criteria.[6]
Specification Checklist for Rail Glazing
For engineers specifying FRA-compliant glazing for a passenger car or locomotive program:
- Certification type — assign Type I or Type II to every window position using the 50-degree definition, and treat curved panels that could fall into either category as end-facing. For Tier II equipment, add the Section 238.421 end-facing requirement and FRA TYPE IHP marking.
- Test data — request the Appendix A test verification data for the specific glazing construction, including the specimen size tested, and confirm it covers the largest panel in the order.
- Marking — confirm the content and location of the permanent FRA Type I or Type II marking so it stays visible after installation.
- Flammability and smoke — for passenger equipment, request ASTM E 162 and E 662 results under Part 238 Appendix B for the interior glazing.
- Retention and egress — review window retention, including the train-passing pressure load in Section 238.221 for Tier I equipment, together with the emergency exit and rescue access removal methods.
- Abrasion and chemicals — specify abrasion and chemical resistance separately, since Part 223 tests impact only.
Vandalism-Resistant Transit Windows: What the Testing Data Actually Shows covers abrasion from cleaning and graffiti removal in transit service.
Five Star's Rail Glazing Capabilities
Five Star Fabricating supplies polycarbonate windows for mass transit vehicles, including light rail, commuter rail, and high-speed rail cars, with side windows in fixed, sliding, and emergency exit configurations. The Fusionite CGI and CGIII data sheets[7] list compliance with FRA 49 CFR Part 223 ballistic and impact requirements for Type I and Type II, and with Part 238 Appendix B flammability and smoke testing under ASTM E 162 and E 662. The CGIII data sheet describes it as best-in-class abrasion-resistant hard-coated polycarbonate and reports below 2% Taber delta haze at 1,000 cycles per ASTM D1044. As with any Part 223 certification, confirm that the test data covers the thickness, construction, and maximum panel size of the program.
Five Star also laminates polycarbonate with polyvinyl butyral interlayers for multilayer windows and forms complex curved windshields in-house.
- Projectile and multiaxial impact — ASTM F22, ISO 6603-2, SAE J1615
- Internal cannon and ball drop testing — in-house
- Optical and abrasion — ASTM D1003, ASTM D1044
Details are on Five Star's lab testing capabilities[8] page. Part 223 compliance rests on test data that matches the glazing being installed, so the window schedule, panel sizes, and certification type for each position are the inputs a rail program needs to settle first. Sharing those inputs with Five Star at the start of a program allows the glazing construction and supporting data to be scoped against the actual requirements.
References
- 49 CFR Part 223: Safety Glazing Standards, Locomotives, Passenger Cars and Cabooses
- 49 CFR 238.221: Glazing (Tier I Passenger Equipment)
- 49 CFR 238.421: Glazing (Tier II Passenger Equipment)
- 49 CFR 238.113: Emergency Window Exits
- 49 CFR 238.114: Rescue Access Windows
- 49 CFR Part 238, Appendix B: Test Methods and Performance Criteria for the Flammability and Smoke Emission Characteristics of Materials Used in Passenger Cars and Locomotive Cabs
- Five Star Fabricating: Fusionite Data Sheets
- Five Star Fabricating: Lab Testing Capabilities
Related Reading
ApplicationMass Transit GlazingSide windows and windshields for buses, light rail, commuter rail, and high-speed rail.
ArticleVandalism-Resistant Transit WindowsWhat abrasion and graffiti-removal testing shows for transit glazing.
QualityInside the Twin Lakes Test LabImpact, optical, abrasion, and chemical testing run in-house to ASTM, ISO, and SAE methods.
Scope Your Rail Glazing With an Engineer
Discuss glazing specifications for a rail vehicle platform, or request test data for a specific coating grade and window schedule.